What is the PuriLab UPW Box?
The PuriLab UPW Box is a Point-of-Use terminal polishing module aimed at ICP-MS, trace analysis, and semiconductor micro-contamination analysis. It connects inline at the back end of an existing UPW / DI water / 18.2 MΩ·cm system.
How is it different from a standard 18.2 MΩ·cm ultrapure-water system?
18.2 MΩ·cm typically describes resistivity. PuriLab focuses on end-of-analysis background control — adding value polishing for low-metal, low-Boron, low-Silicon, and nano-particle risks. The two complement each other.
Why does ICP-MS still need point-of-use polishing?
End-of-line piping and the local environment can still introduce background interference. Terminal polishing placed at the last stage before analysis helps reduce method-blank variation and improves data stability.
Which background elements can it reduce?
Common targets are Na, K, Ca, Mg, Fe, Zn, Al, plus Boron, Silicon, and colloidal particles in specific cases. Actual results depend on feed water and configuration.
Can Boron and Silicon be further reduced?
Yes — boron removal media or a silicon / colloidal silica control configuration can be added on request. Common reference targets are B < 5 ppt and Si < 10 ppt, but actual figures must be verified under your conditions.
Is the < 2 ppt metal background a guaranteed figure?
No. < 2 ppt is a target / reference figure, not a guarantee. The actual result depends on feed-water quality, flow rate, consumable condition, sampling method, and analytical method.
Which use cases suit 1 nm / 5 nm terminal filtration?
It suits nano-particle control, colloidal silica / colloidal iron risk management, semiconductor micro-contamination analysis, and high-cleanliness sample preparation workflows.
Can it connect downstream of an existing UPW or benchtop water system?
Yes. The product is designed as a terminal add-on module. Common installation points are the facility UPW outlet, the back end of a benchtop water system, or the sample-preparation area before analysis.
Is it suitable for semiconductor micro-contamination analysis or VPD / ICP-MS?
Yes — it suits semiconductor micro-contamination analysis, VPD / ICP-MS water, and low-background sample preparation workflows. We recommend confirming target elements and method conditions before deployment.
Can it be used for the final rinse of PFA labware?
Yes — it can serve as one of the sources of final-rinse water for PFA labware, helping to reduce background contamination risk in the rinse step.
What information should we share before deployment?
Please share your feed-water source and recent water-quality data, target elements / method, daily consumption and peak flow, installation space and connection conditions, plus any document requirements (e.g. CoA or validation data).
Can we request on-site testing or a pre/post water-quality comparison?
Yes — depending on the project, we can discuss on-site testing and pre/post water-quality comparison plans to help evaluate deployment benefits and configuration feasibility.