Ultra-trace AnalyticsUltra-trace Analytics

Product items

PTFE Sieve

PTFE sieves are made of high-purity polytetrafluoroethylene in a one-piece, weld-free construction, offering corrosion resistance, low background contamination risk, and good chemical stability. They suit high-cleanliness sieving, powder and granule sample handling, semiconductor material pretreatment, acidic samples, and trace-analysis workflows, and can be used with PTFE trays and lids.

Material: PTFE

PTFE sieve in a one-piece, weld-free construction, usable with PTFE trays and lids, suited to high-cleanliness sieving and corrosion-resistant sample handling workflows

Applications

High-cleanliness sievingPowder sample handlingGranule sample classificationSemiconductor material pretreatmentTrace analysis pretreatmentCorrosion-resistant sievingAcidic sample handling

Available specifications

Share your use case, material, capacity, or size requirements for evaluation.

Product description

PTFE sieves are made of high-purity polytetrafluoroethylene in a one-piece, weld-free construction, offering corrosion resistance, low background contamination risk, and good chemical stability. They suit high-cleanliness sieving, powder and granule sample handling, semiconductor material pretreatment, acidic samples, and trace-analysis workflows, and can be used with PTFE trays and lids.

PTFE Sieve

PTFE Sieve PTFE sieves are made of high-purity polytetrafluoroethylene in a one-piece, weld-free construction, offering corrosion resistance, low background contamination risk, and good chemical stability. They suit high-cleanliness sieving, powder and granule sample handling, sieving of acidic or corrosive samples, semiconductor material pretreatment, and trace-analysis workflows. They can be used with PTFE trays and lids, and custom configurations can be discussed by opening size, dimensions, and use case.

In high-cleanliness sieving, material and structure affect contamination risk and cleaning control

One-piece, weld-free construction helps reduce residue risk

Compared with structures that have joints, a one-piece, weld-free construction lowers the risk of crevice residue and cleaning dead zones, making it better suited to high-cleanliness sample handling.

Corrosion resistance must be confirmed against the actual chemicals

When HF, strong acids, strong bases, or corrosive chemicals are involved, we recommend confirming the chemical concentration, contact time, and safety requirements before selection.

Opening size and mesh count should be chosen by particle size and sieving purpose

Sieve selection should consider the sample particle-size range, the intended classification purpose, and downstream cleaning and storage conditions, rather than judging by a single opening size.

PTFE sieves designed for high-cleanliness sieving and corrosion-resistant sample handling

High-purity PTFE

Made of high-purity polytetrafluoroethylene, suited to high-cleanliness laboratory workflows and corrosion-resistant chemical handling.

One-piece, weld-free

The one-piece, weld-free construction lowers the risk of residue at joints and cleaning dead zones.

Corrosion resistance and chemical stability

Can be used in sieving workflows for acidic samples and corrosive conditions; actual suitability must be confirmed against sample characteristics, operating conditions, and cleanliness requirements.

Low background contamination risk

Suited to semiconductor material pretreatment and trace-analysis pretreatment where background control matters.

Usable with PTFE trays and lids

Forms an integrated workflow for sample sieving, collection, temporary holding, and protection, and custom configurations can be discussed on request.

Application Scenarios

Application scenario tags

  • • High-cleanliness sieving
  • • Powder sample handling
  • • Granule sample classification
  • • Semiconductor material pretreatment
  • • Trace analysis pretreatment
  • • Corrosion-resistant sieving
  • • Acidic sample handling
  • • PTFE sieve
  • • Used with PTFE trays
  • • Low background contamination risk workflows
  • • Custom PTFE sieve

How to confirm the right specification quickly

When requesting a quotation, we recommend providing the following information so the PTFE sieve specification and pairing can be confirmed quickly.

  • ☑ Required outer diameter; the current standard outer diameter is 200 mm
  • ☑ Required opening size: 0.15, 0.25, 0.5, 1, 1.5, 2, 3, 4, 5, 9.5, or 10 mm
  • ☑ Whether a specific mesh count is needed
  • ☑ Sample form: powder, granules, crystals, solid fragments, or chemical samples
  • ☑ Sample particle-size range and intended sieving purpose
  • ☑ Whether HF, strong acids, strong bases, solvents, or corrosive chemicals are involved
  • ☑ Whether a PTFE tray, lid, or collection container is needed
  • ☑ Cleaning method, acid-wash needs, and clean-storage requirements
  • ☑ Whether it is used in semiconductor, high-cleanliness, or trace-analysis workflows
  • ☑ Whether a custom outer diameter, opening size, thickness, frame height, or special structure is needed
  • ☑ Estimated quantity and lead time

PTFE Sieve Specifications

Outer diameterOpening size
200 mm0.15 mm
200 mm0.25 mm
200 mm0.5 mm
200 mm1 mm
200 mm1.5 mm
200 mm2 mm
200 mm3 mm
200 mm4 mm
200 mm5 mm
200 mm9.5 mm
200 mm10 mm
Size OptionsCapacity (mL)
Outer diameter200 mm
Opening size0.15, 0.25, 0.5, 1, 1.5, 2, 3, 4, 5, 9.5, 10 mm

PTFE sieves can be used in powder, granule, crystal, chemical sample, and semiconductor material pretreatment workflows, and are especially suited to applications that need to reduce the risk of metal contamination, weld-seam residue, or cleaning dead zones. Actual suitability must be confirmed against sample particle size, chemical type, cleaning method, operating temperature, mechanical load, and cleanliness requirements.

Need to confirm outer diameter, opening size, mesh count, or tray pairing? Share your sample information and operating conditions, and we can help quickly compare feasible specifications.

Using PTFE trays and lids together

Key points of the combined workflow

  • • The sieved sample can be caught by the tray
  • • The lid can reduce the risk of airborne dust or operating-environment contamination
  • • PTFE helps reduce material-compatibility risk when in contact with acidic or corrosive samples

Key points for configuration

  • • Sieve size and tray size
  • • Sample volume and opening size
  • • Cleaning method and operating workflow
  • • Actual configuration must be confirmed against sample characteristics, operating conditions, and cleanliness requirements

FAQ

What applications are PTFE sieves suited to?

They suit high-cleanliness sieving, powder and granule sample handling, semiconductor material pretreatment, corrosion-resistant sample screening, acidic sample handling, and trace-analysis pretreatment. Actual suitability must be confirmed against sample particle size, chemicals, cleaning method, and cleanliness requirements.

Can PTFE sieves be used with trays and lids?

Yes. PTFE sieves can be used with PTFE trays and lids, which helps with sample collection, temporary holding, protection, and lowering the risk of external contamination. Actual configuration must be confirmed against size, opening size, sample volume, and operating workflow.

Why are PTFE sieves made in one piece without welding?

A one-piece, weld-free construction lowers the risk of weld-seam crevices, joint residue, and cleaning dead zones, and is better suited to high-cleanliness, corrosion-resistant, low-background-contamination sample handling.

Can PTFE sieves be used for strong acid or HF-related samples?

PTFE is commonly used in corrosive chemical environments and can be one material option for strong-acid or HF-related sample handling, but it must still be confirmed against chemical concentration, temperature, contact time, sample form, cleaning method, and laboratory safety requirements.

Can PTFE sieves be customized?

Yes. Outer diameter, opening size, thickness, frame height, tray and lid pairing, special structures, and other custom needs can be discussed.

What should I watch for in trace analysis?

For ppb / ppt-level trace analysis, we recommend confirming the cleaning procedure, acid-wash conditions, blank verification, storage method, and operating environment to reduce background contamination risk.

Need to confirm PTFE sieve opening size, mesh count, or tray pairing configuration?

Please provide the sample form, particle-size range, opening-size needs, whether PTFE trays and lids are needed, chemical conditions, and cleanliness requirements, and we can help confirm a suitable specification and custom configuration.

Request a quote

Not sure about the spec? Upload a photo of your current part and we'll match it.

* Required

Application, chemicals, dimensions or anything else that helps us match the right item.

You can email photos to sales@ultra-trace.com.