Ultra-trace AnalyticsUltra-trace Analytics

Product items

PTFE Digestion Tube (Screw Cap, Reflux)

The PTFE Digestion Tube suits acid digestion, sample preparation, chemical reactions, handling of acidic and alkaline liquids, and high-cleanliness laboratory workflows. A screw cap or reflux cap can be paired on request, and a 50 mL size is offered.

Material: PTFE

PTFE digestion tube, 50 mL, outer diameter 29 mm, height 134 mm, can be paired with a screw cap or reflux cap, for acid digestion and sample preparation

Applications

Acid digestionReflux digestionICP-MS / ICP-OES sample preparationR&D and QC sample processing

Available specifications

50 mL

Model
—
Material
PTFE
Size
OD 29 mm × height 134 mm
Note
Can be fitted with a screw cap or reflux cap as needed for sample digestion and chemical pretreatment

Product description

The PTFE Digestion Tube suits acid digestion, sample preparation, chemical reactions, handling of acidic and alkaline liquids, and high-cleanliness laboratory workflows. A screw cap or reflux cap can be paired on request, and a 50 mL size is offered.

Why choose a PTFE digestion tube

PTFE digestion tubes are commonly used in sample digestion, acid digestion, chemical sample preparation, and laboratory reaction workflows that need chemical resistance, high cleanliness, and low background-contamination risk. Compared with ordinary glass, PP, or PE containers, PTFE is better suited to some acidic and alkaline liquids, organic reagents, high-purity chemicals, and semiconductor or trace-analysis sample preparation. A screw cap or reflux cap can be paired on request, supporting temporary holding, closed handling, or reflux-related workflows. For heated digestion, strong-acid handling, or trace metal analysis, we recommend also confirming the chemical type, temperature, cap type, cleaning procedure, and blank-verification needs. Actual suitability must be confirmed against chemical type, concentration, temperature, heating method, reaction time, cap type, cleaning procedure, and manner of use.

Key Features

Corrosion-resistant PTFE material

Suited to sample-preparation workflows involving acids, bases, organic reagents, and high-purity chemicals, helping reduce contamination variables from ordinary container materials.

Suited to sample digestion

Can be used for acid digestion, sample digestion, chemical sample preparation, and reaction and temporary-holding workflows; actual conditions must be confirmed against the sample and method.

Can be paired with a screw cap

A screw cap can be paired on request, for temporary sample holding, transfer, or closed handling; actual sealing performance must be confirmed against conditions.

Can be paired with a reflux cap

A reflux cap can be paired on request, for reflux or specific sample-preparation workflows; the actual configuration must be confirmed against reaction conditions.

50 mL specification

A 50 mL size is offered, with an outer diameter of 29 mm and a height of 134 mm, suiting laboratory sample preparation and digestion workflows.

Customizable on request

Custom configurations can be evaluated according to capacity, outer diameter, height, cap type, ports, or special sample-preparation needs.

Confirming screw cap, reflux cap, and digestion conditions

PTFE digestion tubes can be paired with a screw cap or reflux cap on request. For strong-acid digestion, reflux sample preparation, high-purity chemicals, semiconductor samples, or trace-analysis workflows, we recommend also confirming the sample type, acid system, digestion temperature, heating method, cap type, cleaning procedure, and blank-verification needs. Actual suitability must be confirmed against chemical type, concentration, temperature, heating method, reaction time, cap type, cleaning procedure, and manner of use.

  • ☑ Required specification: 50 mL
  • ☑ Sample type: water sample, solid sample, chemical sample, semiconductor sample, or other sample
  • ☑ Acid system, base, or organic reagent used
  • ☑ Chemical concentration, operating temperature, and reaction time
  • ☑ Whether threaded caps are needed
  • ☑ Whether a reflux cap is needed
  • ☑ Whether closed handling, reflux handling, or temporary-holding workflows are needed
  • ☑ Whether it is used for ICP-MS, ICP-OES, AAS, or trace analysis
  • ☑ Whether it is used in semiconductor, high-cleanliness, or high-purity chemical workflows
  • ☑ Whether acid-wash, cleaning, blank-verification, or clean-storage procedures are needed
  • ☑ Whether a custom capacity, size, cap type, or special configuration is needed
  • ☑ Estimated quantity and lead time

How can we quickly confirm a suitable specification?

To help confirm a suitable PTFE digestion tube, cap type, and customization needs, we recommend providing the following information:

  • • Required capacity or single-sample volume
  • • Sample type and analytical method
  • • Acid system, base, or organic reagent used
  • • Chemical concentration, operating temperature, and reaction time
  • • Whether a screw cap or reflux cap is needed
  • • Whether heating, reflux, temporary holding, or closed handling is needed
  • • Whether it is used in semiconductor, high-cleanliness, or trace-analysis workflows
  • • Analytical method, e.g. ICP-MS, ICP-OES, AAS
  • • Whether high-cleanliness cleaning, acid washing, or blank verification is needed
  • • Whether a custom capacity, size, or cap type is needed
  • • Estimated quantity and lead time

How to choose a PTFE digestion tube specification

  • • 50 mL: suited to general laboratory sample digestion, acid digestion, chemical sample preparation, and small-batch analytical workflows
  • • If a screw cap is needed: suited to temporary sample holding, transfer, low-evaporation-risk control, or closed-handling needs, but actual sealing performance must be confirmed
  • • If a reflux cap is needed: suited to reflux or specific heated sample-preparation workflows; temperature, time, acid system, and setup pairing need to be confirmed
  • • For trace-analysis use: pair with the lab's existing cleaning, acid-wash, blank-verification, and clean-storage procedures
  • • If used for semiconductor samples: please confirm the wetted material, chemical conditions, cleaning procedure, and analytical blank requirements
  • • If strong acids, strong bases, or special organic reagents are involved: suitability must be confirmed against chemical type, concentration, temperature, heating method, and reaction time
  • • If customization is needed: please provide the target capacity, outer diameter, height, cap type, port requirements, and conditions of use

FAQ

Are a PTFE digestion tube and a PTFE digestion vessel the same kind of product?

Yes. In most scenarios the two names refer to the same kind of sample-preparation container. Laboratories in Taiwan more commonly say "digestion tube", while the product image says "digestion vessel"; the English name is PTFE Digestion Tube.

Which applications suit a PTFE digestion tube?

A PTFE digestion tube suits acid digestion, sample preparation, chemical reactions, handling of acidic and alkaline liquids, and high-cleanliness laboratory workflows. Actual suitability still needs to be confirmed against chemical type, concentration, temperature, reaction time, and manner of use.

Can it be paired with a screw cap?

Yes. The image data mentions it can be used with a screw cap. The actual cap type, sealing performance, and supply method must be confirmed on request.

Can it be paired with a reflux cap?

Yes. The image data mentions it can be used with a reflux cap. If it will be used for reflux or heated sample-preparation workflows, we recommend also confirming the acid system, temperature, reaction time, and setup configuration.

Can a PTFE digestion tube be used with acids, bases, or organic solvents?

PTFE can be used in workflows involving many acids, bases, and some organic reagents, but actual suitability must be confirmed against chemical type, concentration, temperature, heating method, contact time, and safety rules.

What specifications are currently available?

The image data currently lists a 50 mL size, with an outer diameter of 29 mm and a height of 134 mm.

Can this be customized?

Custom capacity, size, screw cap, reflux cap, or special configurations can be evaluated on request. Actual feasibility must be confirmed against dimensions, quantity, manufacturing conditions, and use requirements.

What information should we share when inquiring about specifications?

We recommend providing the required capacity, sample type, acid system or reagent, operating temperature, reaction time, whether a screw cap or reflux cap is needed, whether it is used for trace analysis or high-cleanliness workflows, and estimated quantity.

Need to confirm PTFE digestion tube specifications, screw cap, or reflux-cap configuration?

Please provide the sample type, acid system or reagent, operating temperature, reaction time, whether a screw cap or reflux cap is needed, and whether it is used in high-cleanliness or trace-analysis workflows, and we can help confirm a suitable configuration.

Request a quote

Not sure about the spec? Upload a photo of your current part and we'll match it.

* Required

Application, chemicals, dimensions or anything else that helps us match the right item.

You can email photos to sales@ultra-trace.com.