Spec
- Model
- —
- Material
- —
- Size
- —
- Note
- —
Product items
The PFA Volumetric Flask is made of PFA with Class A volumetric accuracy, a PFA screw cap, good sealing, resistance to strong acids and bases, and low metal-ion content, suited to semiconductor trace analysis, ICP-MS sample preparation, preparation of high-purity acid and base solutions, standards preparation, and high-cleanliness make-up-to-volume handling. Sizes from 10 mL to 1000 mL are offered, with an optional calibration / metrology certificate.
Material: PFA

| Spec | Model | Material | Size | Note |
|---|---|---|---|---|
| — | — | — | — | — |
| — | — | — | — | — |
| — | — | — | — | — |
| — | — | — | — | — |
| — | — | — | — | — |
| — | — | — | — | — |
| — | — | — | — | — |
The PFA Volumetric Flask is made of PFA with Class A volumetric accuracy, a PFA screw cap, good sealing, resistance to strong acids and bases, and low metal-ion content, suited to semiconductor trace analysis, ICP-MS sample preparation, preparation of high-purity acid and base solutions, standards preparation, and high-cleanliness make-up-to-volume handling. Sizes from 10 mL to 1000 mL are offered, with an optional calibration / metrology certificate.
A Class A PFA volumetric flask designed for make-up to volume of high-purity acids and bases, standards preparation, and trace-analysis sample preparation. Ultra-trace Analytics offers the PFA Volumetric Flask, made of PFA, with Class A volumetric accuracy, a PFA screw cap, good sealing, resistance to strong acids and bases, and low metal-ion content, suited to high-cleanliness laboratories, semiconductor trace analysis, ICP-MS sample preparation, preparation of high-purity acid and base solutions, standards preparation, and low-background contamination control workflows. Capacities from 10 mL to 1000 mL are offered, and calibration / metrology certificates can be confirmed on request.
Made of PFA, suited to scenarios related to cleanroom volumetric flasks, trace analysis labware, and semiconductor labware.
The Class A volumetric tolerance corresponding to each capacity is provided, suiting standards preparation, calibration-solution preparation, and ICP-MS sample preparation.
Paired with a PFA screw cap, suited to temporary holding, mixing, and transfer after preparation, reducing the background-contamination risk in the workflow.
Suited to many high-purity chemical make-up-to-volume workflows. Actual chemical compatibility must be confirmed against chemical type, concentration, temperature, contact time, and conditions of use.
Helps reduce background interference in trace-analysis workflows, suiting semiconductor contamination control and low-background handling needs.
A metrology certificate, one per flask, can be provided on request and is charged separately; please inquire about actual content and supply method.
Not sure which capacity to choose or whether a metrology certificate is needed? Please provide the liquid to be prepared, target capacity, conditions of use, and QA requirements, and we can help confirm a suitable PFA volumetric flask specification.
Class A volumetric accuracy means the capacity error of the volumetric flask must meet the permissible tolerance for its capacity. For example, for a 10 mL PFA volumetric flask, a volumetric error within ±0.02 mL meets the Class A volumetric requirement listed in this product's data. A metrology certificate, one per flask, can be provided for PFA volumetric flasks on request. The certificate is charged separately, and the actual certificate content, delivery method, and fee should be confirmed before ordering.
The PFA volumetric flask suits high-cleanliness laboratories, semiconductor trace analysis, ICP-MS sample preparation, trace metals analysis, preparation of high-purity acid and base solutions, standards preparation, make-up to volume of dilution liquids, and low-background contamination control workflows.
Glass volumetric flasks suit general make-up-to-volume use but are not necessarily suited to HF or some strongly corrosive chemicals. The PFA volumetric flask is made of PFA and suits make-up-to-volume handling with high-cleanliness, high-purity acid and base, and low-background contamination control needs.
Class A volumetric accuracy means the capacity error of the volumetric flask must meet the permissible tolerance for its capacity. For example, in this product's data, the Class A permissible tolerance for the 10 mL PFA volumetric flask is ±0.02 mL.
Per current product data, capacities include 10, 25, 50, 100, 250, 500, and 1000 mL, with Class A permissible tolerances of ±0.02, ±0.03, ±0.05, ±0.10, ±0.15, ±0.25, and ±0.40 mL respectively.
A metrology certificate, one per flask, can be provided on request, and the certificate is charged separately. Please confirm the actual certificate content, fee, and delivery method with Ultra-trace Analytics before ordering.
PFA is commonly used in many high-cleanliness chemical-handling scenarios, but actual suitability must be confirmed against chemical type, concentration, operating temperature, contact time, and handling conditions. For HF, strong acids, strong bases, or special chemicals, we recommend providing conditions for confirmation first.
PFA and its low metal-ion content help reduce the risk of background contamination, but actual contamination control still depends on the cleaning method, storage method, operating environment, reagent purity, cap configuration, and laboratory SOP.
The PFA volumetric flask can be used for ICP-MS or trace metals analysis-related standards preparation, sample dilution, make-up to volume of acid and base solutions, and sample-preparation workflows. Actual suitability still needs to be confirmed against the sample matrix, cleaning workflow, and analytical goal.
Please provide your liquid to be prepared, capacity requirement, whether a calibration / metrology certificate is needed, conditions of use, and whether it is used for ICP-MS / trace metals analysis. Ultra-trace Analytics can help confirm a suitable PFA Volumetric Flask specification and application fit. The above specifications are compiled from product data. Please contact Ultra-trace Analytics to confirm actual supplied specifications, cap configuration, calibration / metrology certificate content, certificate fee, stock status, and chemical compatibility. For use with HF, strong acids, strong bases, organic solvents, or special matrices, we recommend providing the chemical type, concentration, operating temperature, contact time, and handling conditions.