Ultra-trace AnalyticsUltra-trace Analytics

Product items

PFA High-Purity Syringe Dispenser

A high-cleanliness PFA injection tool designed for aliquoting of high-purity liquids, small-volume addition, and low-contamination sampling.

Ultra-trace Analytics offers the PFA Syringe, made of PFA and paired with a high-purity PTFE plunger, which can be connected to PFA tubing and suits high-cleanliness laboratories, semiconductor trace analysis, ICP-MS sample preparation, and small-volume addition, withdrawal, aliquoting, and sample transfer of high-purity liquids. The product is offered in 10 mL and 20 mL sizes, and fit can be confirmed against the actual liquid type, handling method, and cleanliness needs.

  • • Made of PFA
  • • Paired with a high-purity PTFE plunger
  • • Can be connected to PFA tubing
  • • Suited to small-volume addition, withdrawal, and liquid aliquoting
  • • 10 mL / 20 mL sizes offered
  • • Suited to high-cleanliness laboratories and semiconductor trace-analysis workflows

Material: PFA

PFA High-Purity Syringe Dispenser

Applications

Small-volume dispensing of high-purity chemicalsTrace analysis samplingSmall-volume standard solution handlingHigh-cleanliness lab work

Available specifications

Spec

Model
—
Material
—
Size
—
Note
—

Spec

Model
—
Material
—
Size
—
Note
—

Product description

The PFA syringe is made of PFA and paired with a high-purity PTFE plunger; it can be used with PFA tubing and suits high-cleanliness laboratories, semiconductor trace analysis, ICP-MS sample preparation, aliquoting of high-purity liquids, small-volume addition, and low-contamination sampling workflows. 10 mL and 20 mL sizes are offered; please inquire about application fit.

In trace analysis, sampling and addition tools can also affect background contamination

Ordinary syringes may be unsuitable for high-purity chemicals

In high-purity acids and bases, electronic-grade solvents, ICP-MS sample preparation, or semiconductor trace analysis, ordinary plastic or metal contact parts may not meet low background-contamination needs.

Small-volume addition needs a stable, controllable handling tool

In sample preparation, dilution, spike addition, standards transfer, or small-volume withdrawal, tool material, handling feel, and the risk of liquid residue can all affect workflow stability.

Tubing connections affect how liquids are withdrawn and aliquoted

If liquid must be withdrawn from a container, tubing, or a deeper position, a PFA syringe paired with PFA tubing adds handling flexibility. The actual connection method and dimensions must be confirmed against the supplied specification.

Low-concentration analysis needs control of every contact surface

In analysis at the ppt, sub-ppt, or ppq level, the syringe, plunger, tubing, containers, and operating environment can all contribute background contamination. Tool selection needs to be paired with cleaning and storage SOPs.

A PFA syringe designed for high-cleanliness sampling and dispensing

PFA material

Made of PFA, suited to high-cleanliness laboratories, dispensing of high-purity liquids, and semiconductor trace-analysis-related operations.

High-purity PTFE plunger

Paired with a high-purity PTFE plunger, suited to liquid addition, aspiration, and dispensing workflows that need to reduce background-contamination risk.

Can be connected to PFA tubing

Can be paired with PFA tubing for aspiration or addition, suiting scenarios that need extended sampling, tubing-based dispensing, or specific container configurations. The actual connection method must be confirmed against the specification.

Small-volume addition and aspiration

Suited to small-volume liquid dispensing, sample transfer, addition of standards, withdrawal of dilution liquids, and high-cleanliness liquid aliquoting.

Low-contamination handling workflow

Suited to use with high-cleanliness laboratory SOPs, acid-wash procedures, blank-control procedures, and trace-analysis sample preparation.

Two capacity specifications

Per product data, 10 mL and 20 mL are offered, selectable by sampling volume, aliquot volume, and handling preference.

Suitable applications

Semiconductor trace-contamination analysis

  • • Small-volume sampling of high-purity liquids
  • • ICP-MS / ICP-MS/MS sample preparation
  • • Addition of standards or spike solutions
  • • Semiconductor chemical analysis workflows

High-cleanliness liquid aliquoting

  • • Aliquoting of high-purity acids and bases, confirmed per compatibility
  • • Aliquoting of high-purity water, dilution liquids, and cleaning solutions
  • • Transfer of small reagent volumes
  • • Liquid transfer between PFA / PTFE / FEP containers

Laboratory withdrawal and addition operations

  • • Small-volume addition
  • • Small-volume withdrawal
  • • Extended sampling with PFA tubing
  • • Withdrawal from specific containers or tubing positions

R&D and QA workflows

  • • Liquid transfer for method development
  • • Batch sample aliquoting
  • • Aliquoting before storage of high-cleanliness samples
  • • Customer-specified sample-preparation workflows

How to choose a suitable PFA syringe?

Not sure whether to choose 10 mL or 20 mL, or whether it needs to be paired with PFA tubing? Please provide the liquid type, sampling volume, handling method, and analytical purpose, and we can help confirm a suitable PFA syringe specification.

  • ☑ Purpose: small-volume addition / small-volume withdrawal / aliquoting / sample transfer / withdrawal through tubing
  • ☑ Liquid type: acid, base, solvent, high-purity water, cleaning solution, standard, or sample solution
  • ☑ Required capacity: 10 mL or 20 mL
  • ☑ Volume per sampling or addition
  • ☑ Whether connection to PFA tubing is needed
  • ☑ Whether it is used for trace analysis, ICP-MS sample preparation, or semiconductor contamination control
  • ☑ Whether contact with metal or ordinary plastic must be avoided
  • ☑ Chemical concentration, operating temperature, and contact time
  • ☑ Whether it needs to be paired with PFA / PTFE / FEP reagent bottles, trays, tubing, or other high-cleanliness tools
  • ☑ Whether the lab has SOP, blank-control, or cleaning-procedure requirements

Product specifications

Product namePFA Syringe
English namePFA Syringe
Body materialPFA
Plunger materialHigh-purity PTFE
Manner of useCan be connected to PFA tubing; the actual connection method is confirmed per supplied specification
Main usesSmall-volume addition, withdrawal, aliquoting of high-purity liquids, sample transfer
Suitable scenariosHigh-cleanliness laboratories, semiconductor trace analysis, ICP-MS sample preparation, handling of high-purity chemicals
Capacity specifications10 mL, 20 mL
Selection informationPlease provide the liquid type, sampling volume, addition volume, whether connection to PFA tubing is needed, operating environment, and cleanliness requirements
Size OptionsCapacity (mL)
Size 110
Size 220

The above specifications are compiled from product data. Please contact Ultra-trace Analytics to confirm actual supplied specifications, connection method, PFA tubing compatibility, cleaning method, and chemical compatibility. For sampling of high-purity acids and bases, organic solvents, or special matrices, we recommend providing the liquid type, concentration, temperature, contact time, and handling conditions.

Not sure whether to choose 10 mL or 20 mL, or whether it needs to be paired with PFA tubing? Feel free to inquire to confirm capacity, connection method, and chemical compatibility.

Differences between a PFA syringe and an ordinary laboratory syringe

Ordinary plastic or glass syringe

  • • Not necessarily suited to high-purity acids and bases or special chemicals
  • • May not meet semiconductor low-contamination sampling needs
  • • Contact materials and background contamination need additional evaluation
  • • Better suited to general liquid transfer or low-cleanliness operations

PFA syringe

  • • Made of PFA
  • • Paired with a high-purity PTFE plunger
  • • Can be connected to PFA tubing
  • • Suited to small-volume addition, withdrawal, and high-cleanliness liquid aliquoting
  • • Suited to semiconductor trace analysis and low-contamination sample preparation

FAQ

Q1: Which applications suit the PFA syringe?

The PFA syringe suits high-cleanliness laboratories, semiconductor trace analysis, ICP-MS sample preparation, aliquoting of high-purity liquids, small-volume addition, small-volume withdrawal, sample transfer, and handling workflows that need to reduce background-contamination risk.

Q2: How does a PFA syringe differ from an ordinary plastic syringe?

The PFA syringe is made of PFA and paired with a high-purity PTFE plunger, suiting high-cleanliness and low-contamination sampling needs. Ordinary plastic syringes suit general use, and in high-purity chemicals or trace analysis their material contact and background-contamination risk need to be evaluated.

Q3: Can the PFA syringe be connected to PFA tubing?

Per product data, the PFA syringe can be connected to PFA tubing, suiting extended withdrawal, tubing-based aliquoting, or sampling from special containers. The actual connection method, dimensions, and compatibility must be confirmed against the supplied specification.

Q4: What capacities are available for the PFA syringe?

Per current product data, capacity specifications include 10 mL and 20 mL. Please contact Ultra-trace Analytics to confirm actual supply status and other specification needs.

Q5: Can the PFA syringe be used with high-purity acids and bases?

PFA is commonly used in many high-cleanliness chemical-handling scenarios, but actual suitability must be confirmed against chemical type, concentration, temperature, contact time, and conditions of use. For HF, strong acids, strong bases, organic solvents, or special matrices, we recommend providing conditions for confirmation first.

Q6: Will the PFA syringe cause no contamination at all?

PFA and high-purity PTFE help reduce the risk of background contamination, but actual contamination control still depends on the cleaning method, storage method, operating environment, liquid purity, PFA tubing configuration, and laboratory SOP. For analysis at the ppt or ppq level, we recommend pairing it with an appropriate blank-control procedure.

Q7: Can the PFA syringe be used for ICP-MS sample preparation?

The PFA syringe can be used for ICP-MS or trace metals analysis-related reagent addition, withdrawal of sample liquids, transfer of standards, addition of spike solutions, and aliquoting of sample-preparation liquids. Actual suitability still needs to be confirmed against the sample matrix, cleaning workflow, and contamination-control requirements.

Need a high-cleanliness PFA syringe?

Please provide your liquid type, sampling volume, addition volume, whether connection to PFA tubing is needed, operating environment, and whether it is used for ICP-MS / trace metals analysis. Ultra-trace Analytics can help confirm a suitable PFA Syringe specification and application fit.

Request a quote

Not sure about the spec? Upload a photo of your current part and we'll match it.

* Required

Application, chemicals, dimensions or anything else that helps us match the right item.

You can email photos to sales@ultra-trace.com.