250 mL
- 外徑 mm
- 81
- 高度 mm
- 79
- 備註
- 可依需求確認接嘴與蓋體配置
Product items
PFA gas reaction vessel for corrosive-gas and HF-containing gas-phase reactions and sampling. Suitable for high-cleanliness labs and semiconductor process development.
Material: High-purity PFA

| Spec | 外徑 mm | 高度 mm | 備註 | |
|---|---|---|---|---|
| 250 mL | 81 | 79 | 可依需求確認接嘴與蓋體配置 | |
| 350 mL | 81 | 91 | 可依需求確認接嘴與蓋體配置 | |
| 500 mL | 81 | 137 | 可依需求確認接嘴與蓋體配置 | |
| 1000 mL | 108 | 155 | 可依需求確認接嘴與蓋體配置 | |
| 4000 mL | 176 | 233 | 可依需求確認接嘴與蓋體配置 | |
| 6000 mL | 192 | 270 | 可依需求確認接嘴與蓋體配置 |
PFA gas reaction vessel for corrosive-gas and HF-containing gas-phase reactions and sampling. Suitable for high-cleanliness labs and semiconductor process development.
PFA gas reaction vessels are used in lab reaction workflows where container cleanliness, chemical compatibility, and tubing connectivity matter. PFA suits high-cleanliness chemicals, acidic samples, and trace-analysis-related sample-prep applications. With a 1/4-inch port, the vessel connects to PFA tubing for gas introduction, liquid transfer, series-flow reactions, or lab piping. If a special lid, alternate port location, or specific tubing layout is needed, a custom PTFE / tetrafluoro lid can be evaluated against the actual use conditions.
Suited to semiconductor, chemical-analysis, and trace-analysis reaction workflows sensitive to container material and background contamination.
The vessel has a uniform wall thickness that helps with structural stability in use; actual pressure rating depends on temperature, chemical, and use conditions.
A 1/4-inch port can be configured for easy PFA-tubing connection for gas introduction, liquid transfer, or workflow series connection.
Custom PTFE / tetrafluoro lid configurations — port type, hole positions, tubing connection, and sealing — can be evaluated on request.
Available in 250, 350, 500, 1000, 4000, and 6000 mL — choose based on reaction volume and workflow.
To help confirm the right PFA gas reaction vessel, port, and lid configuration, please share the following:
PFA gas reaction vessels suit high-cleanliness chemical reactions, gas introduction, gas-liquid reaction testing, sample prep, and trace-analysis workflows. Actual suitability is confirmed against chemical, gas type, temperature, pressure, and operating method.
Yes — a 1/4-inch port can be configured and PFA tubing connected. The actual port style, count, and location are confirmed against the workflow and tubing layout.
Yes — custom tetrafluoro / PTFE lids can be evaluated on request, including port hole layout, tubing connections, gas-inlet / vent / sampling configurations. Feasibility is confirmed against size, material, sealing method, and use conditions.
The product features a uniform wall thickness that aids structural stability; the actual rating, however, depends on volume, temperature, pressure, chemical, port, and lid design. For pressurized reactions, please share full use conditions for evaluation.
PFA is used in workflows that need chemical compatibility, high cleanliness, and low background-contamination risk. Compared with glass vessels, PFA reaction vessels fit some acidic or high-cleanliness sample workflows better — but the final choice depends on chemical, temperature, reaction conditions, and analytical goal.
Available in 250, 350, 500, 1000, 4000, and 6000 mL. Outer body diameter and height per volume are in the spec table.
Please share required volume, chemical or gas type, operating temperature/pressure, whether a 1/4-inch port is needed, whether PFA tubing connection is needed, whether a custom tetrafluoro lid is needed, and estimated quantity.
Share required volume, chemical, gas type, temperature/pressure conditions, PFA tubing size, and whether a custom tetrafluoro lid is needed, and we will help confirm a suitable specification.
實際適用壓力、溫度、酸鹼條件、氣體種類、接嘴配置與蓋體設計,需依使用方法與安全規範確認。