20 mL
- 體直徑 mm
- 40
- 總高 mm
- 38
- 備註
- 可搭配 PFA 蓋或 PTFE 蓋
Product items
PFA crucible for sample digestion with HF, strong acids, and strong alkalis, and for low-background-contamination trace-analysis sample prep.
Material: High-purity PFA

| Spec | 體直徑 mm | 總高 mm | 備註 | |
|---|---|---|---|---|
| 20 mL | 40 | 38 | 可搭配 PFA 蓋或 PTFE 蓋 | |
| 30 mL | 40 | 42 | 可搭配 PFA 蓋或 PTFE 蓋 | |
| 50 mL | 50 | 52 | 可搭配 PFA 蓋或 PTFE 蓋 | |
| 100 mL | 61 | 64 | 可搭配 PFA 蓋或 PTFE 蓋 | |
| 250 mL | 85 | 70 | 可搭配 PFA 蓋或 PTFE 蓋 | |
| 500 mL | 101 | 95 | 可搭配 PFA 蓋或 PTFE 蓋 |
PFA crucible for sample digestion with HF, strong acids, and strong alkalis, and for low-background-contamination trace-analysis sample prep.
PFA crucibles are used in sample-prep workflows that need strict control of container cleanliness, chemical compatibility, and sample background contamination. Compared with standard glass or plastic vessels, PFA is the better fit for some acidic samples, high-cleanliness chemicals, and trace-metals analysis applications. The flat base suits hotplate use for sample heating, evaporation, concentration, acid treatment, and lab sample prep. A PFA or PTFE lid can be paired on request to reduce external contamination or sample exposure.
Suited to semiconductor, high-cleanliness lab, and trace-analysis sample-prep workflows. Helps reduce background contamination from generic container materials.
The flat bottom suits hotplate-based sample heating, evaporation-to-dryness, and concentration; actual heating conditions are confirmed against the method.
PFA or PTFE lids can be paired per sample-handling needs to reduce sample exposure, lower external-contamination risk, or aid workflow management.
Suitable for sample prep across ICP-MS, ICP-OES, AAS, etc. — especially for samples sensitive to container background contamination.
Available in 20, 30, 50, 100, 250, and 500 mL — choose based on sample volume, evaporation volume, and workflow.
To help confirm the right PFA crucible volume, lid, and use conditions, please share the following:
PFA crucibles suit high-cleanliness sample prep, hotplate-based evaporation-to-dryness, sample concentration, acid treatment, and trace-metals analysis workflows. Actual suitability is confirmed against sample type, acid system, temperature, and heating time.
Yes — the PFA crucible has a flat base suited to hotplate-based sample heating, evaporation-to-dryness, or concentration workflows. Actual temperature and duration are confirmed against sample and method.
Open-flame heating of the PFA crucible is not recommended. For heating, pair the crucible with a hotplate or another suitable lab heating device per product specifications, and confirm temperature and safety conditions.
Yes — PFA or PTFE lids can be paired on request. The actual lid configuration is confirmed against volume, sample type, heating conditions, and intended use.
PFA is used in sample-prep workflows that need chemical compatibility, high cleanliness, and low background-contamination risk. Compared with glass vessels, PFA crucibles fit some acidic-sample and trace-analysis applications better — but the final choice depends on chemical, temperature, and analytical goal.
Yes — PFA crucibles can be used in sample prep for ICP-MS, ICP-OES, AAS, and similar. For trace-metals analysis, pair with the lab's existing acid-wash, cleaning, blank-verification, and clean-storage procedures.
Available in 20, 30, 50, 100, 250, and 500 mL. Body diameter and total height per volume are in the spec table.
Share required volume, sample type, acid system, heating temperature, whether a PFA / PTFE lid is needed, and analytical method, and we will help confirm a suitable specification.
實際適用溫度、酸鹼條件、加熱時間、蓋體搭配與樣品前處理方法,需依使用條件確認。