Ultra-trace AnalyticsUltra-trace Analytics

Product items

PFA High-Purity Connectors / Fittings

High-purity PFA connectors and fittings for semiconductor high-purity chemical supply, UPW piping, ICP-MS / ICP-OES tubing, and R&D fluid paths. Reduces container-borne contamination in low-background piping systems.

  • • High-purity PFA, suited to high-cleanliness, corrosion-resistant tubing connections
  • • Bead-insert style connection improves the stability of tubing connections
  • • 2-way and 3-way connectors available
  • • Common sizes of 1/8, 1/4, and 1/2 inch
  • • 2-way connectors support 1/4-to-1/8 and 1/4-to-1/2 reducing adaptation
  • • Other sizes can be evaluated through custom tooling on request

Material: PFA

PFA High-Purity Connectors / Fittings

Applications

High-purity chemical pipingUPW pipingICP-MS / ICP-OES tubingHigh-cleanliness lab fluid paths

PFA Connector Specifications

2-way connector

Model
1/8 in, 1/4 in, 1/2 in, 1/4 to 1/8, 1/4 to 1/2
Material
Suited to straight-through connections, tubing extension, and reducing adaptation
Size
PFA
Note
Other sizes can be evaluated through custom tooling on request

3-way connector

Model
1/8 in, 1/4 in, 1/2 in
Material
Suited to flow splitting, merging, bypass, or multi-line piping configurations
Size
PFA
Note
Fitting type and tubing configuration can be confirmed on request

Product description

High-purity PFA connectors and fittings for semiconductor high-purity chemical supply, UPW piping, ICP-MS / ICP-OES tubing, and R&D fluid paths. Reduces container-borne contamination in low-background piping systems.

Why choose PFA fittings

PFA fittings are commonly used in tubing connections that need high cleanliness, corrosion resistance, and low background-contamination risk. Compared with ordinary metal or plastic fittings, PFA is better suited to some acidic and alkaline chemicals, high-purity reagents, semiconductor wet processes, and trace-analysis-related tubing. Two-way fittings suit straight-through connections, tubing extension, and reducing transitions; three-way fittings suit splitting, merging, bypass, or multi-line configurations. Selection must be confirmed against tubing size, fluid type, pressure, temperature, flow rate, and cleaning procedure.

Key Features

High-purity PFA material

Suited to semiconductor, high-cleanliness laboratory, and chemical-tubing workflows, helping reduce the background-contamination risk from ordinary fitting materials.

Flared-bead connection

The flared-bead connection design helps improve the stability and ease of handling of PFA tubing connections; actual sealing performance must be confirmed against conditions of use.

Two-way / three-way options

Two-way fittings suit straight-through connections and transitions; three-way fittings suit splitting, merging, bypass, or multi-line configurations.

Common imperial sizes

Common sizes of 1/8, 1/4, and 1/2 inch are offered, making it easy to pair with existing PFA tubing, valves, and equipment.

Reducing-transition specifications

Two-way fittings come in 1/4 to 1/8 and 1/4 to 1/2 specifications, suiting transitions between different tubing diameters.

Custom tooling can be evaluated

Other sizes or special fittings can be evaluated for customization according to tubing, fitting, equipment, or experimental workflow needs.

Confirming two-way, three-way, and reducing-transition configurations

PFA fittings can be selected as two-way, three-way, or reducing-transition specifications according to the tubing configuration. For semiconductor chemicals, high-purity reagents, acidic and alkaline liquids, or trace-analysis sample-preparation systems, we recommend also confirming the PFA tubing size, fitting type, fluid direction, pressure, flow rate, and cleaning procedure.

  • ☑ Whether a two-way or three-way fitting is needed
  • ☑ Tubing size: 1/8, 1/4, 1/2 inch
  • ☑ Whether a 1/4 to 1/8 or 1/4 to 1/2 reducing transition is needed
  • ☑ Whether custom tooling for other sizes is needed
  • ☑ Tubing material and fitting type
  • ☑ Fluid type, acid system, base, or solvent
  • ☑ Operating temperature and pressure
  • ☑ Estimated flow rate and operating frequency
  • ☑ Whether it is used in semiconductor, high-cleanliness, or trace-analysis workflows
  • ☑ Whether acid-wash, cleaning, or blank-verification procedures are needed
  • ☑ Estimated quantity and lead time

How can we quickly confirm a suitable specification?

To help confirm suitable PFA fittings, sizes, and tubing configuration, we recommend providing the following information:

  • • Whether a two-way or three-way fitting is needed
  • • Tubing size: 1/8, 1/4, or 1/2 inch
  • • Whether a reducing transition is needed, e.g. 1/4 to 1/8 or 1/4 to 1/2
  • • Whether custom tooling for other sizes is needed
  • • Tubing material and fitting type
  • • Fluid type, acid system, base, or solvent
  • • Operating temperature, pressure, and flow rate
  • • Whether it is used in semiconductor, high-cleanliness, or trace-analysis workflows
  • • Whether it needs to be paired with existing PFA tubing, valves, or containers
  • • Photos of existing tubing, photos of fittings, or equipment models
  • • Estimated quantity and lead time

How to choose a PFA fitting specification

  • • Two-way fitting: suited to single-path straight-through connections, tubing extension, equipment-port connection, or reducing transitions.
  • • Three-way fitting: suited to splitting, merging, bypass, diversion, or multi-line configurations.
  • • 1/8 inch: suited to low flow rates, precision tubing, or transfer of small reagent volumes.
  • • 1/4 inch: a configuration commonly used in general laboratory and semiconductor chemical tubing.
  • • 1/2 inch: suited to higher flow rates, main trunk lines, or higher-throughput workflows.
  • • 1/4 to 1/8: suited to transitioning from general 1/4 tubing to low-flow tubing or analytical systems.
  • • 1/4 to 1/2: suited to transitioning from general 1/4 tubing to higher-flow or main trunk tubing.
  • • For trace analysis, we recommend pairing with existing cleaning, acid-wash, blank-verification, and clean-storage procedures.
  • • If strong acids, strong bases, or special solvents are involved, suitability must be confirmed against chemical type, concentration, temperature, pressure, and contact time.

FAQ

Which applications suit PFA fittings?

PFA fittings suit high-cleanliness chemical tubing, transfer of acidic and alkaline liquids, semiconductor wet processes, laboratory fluid control, and trace-analysis sample-preparation systems. Actual suitability still needs to be confirmed against tubing size, chemical, concentration, temperature, pressure, flow rate, and fitting type.

What is the difference between two-way and three-way fittings?

Two-way fittings are mainly used for single-path straight-through connections, tubing extension, or reducing transitions; three-way fittings can be used for splitting, merging, bypass, or multi-line configurations. The actual choice must be confirmed against the tubing flow and fluid direction.

What sizes are currently available?

Two-way fittings come in 1/8 inch, 1/4 inch, 1/2 inch, 1/4 to 1/8, and 1/4 to 1/2; three-way fittings come in 1/8 inch, 1/4 inch, and 1/2 inch.

Can PFA fittings be used with PFA tubing?

How to pair them with PFA tubing, PFA valves, or other fluoropolymer tubing components can be confirmed on request. The actual tube diameter, fitting type, and sealing method must be confirmed against the on-site tubing configuration.

Can PFA fittings be used with acids, bases, or organic solvents?

PFA can be used in workflows involving many acids, bases, and some organic solvents, but actual suitability must be confirmed against chemical type, concentration, temperature, pressure, flow rate, and contact time.

What do 1/4 to 1/8 and 1/4 to 1/2 mean?

These sizes denote reducing transitions, used for connections between different tubing sizes. The actual pairing still needs confirmation of tubing material, fitting type, flow direction, pressure, and sealing needs.

Can other sizes be custom-tooled?

Custom tooling for other sizes or special fittings can be evaluated on request. Actual feasibility must be confirmed against dimensions, quantity, manufacturing conditions, and use requirements.

Are PFA fittings suitable for semiconductor high-cleanliness workflows?

PFA fittings are commonly used in high-cleanliness, corrosion-resistant tubing workflows and can be applied to transfer of semiconductor chemicals and high-purity reagents. For trace-contamination control, we recommend also confirming the cleaning procedure, blank verification, and wetted-material requirements.

What information should we share when inquiring about specifications?

We recommend providing the two-way or three-way requirement, tubing size, whether a reducing transition is needed, fluid type, concentration, temperature, pressure, flow rate, fitting type, whether it is used in a high-cleanliness workflow, and estimated quantity.

Need to confirm PFA fitting size or tubing configuration?

Please provide the two-way / three-way requirement, tubing size, whether a reducing transition is needed, fluid type, temperature and pressure conditions, fitting type, and operating environment, and we can help confirm a suitable specification.

Request a quote

Not sure about the spec? Upload a photo of your current part and we'll match it.

* Required

Application, chemicals, dimensions or anything else that helps us match the right item.

You can email photos to sales@ultra-trace.com.