2-way connector
- Model
- 1/8 in, 1/4 in, 1/2 in, 1/4 to 1/8, 1/4 to 1/2
- Material
- Suited to straight-through connections, tubing extension, and reducing adaptation
- Size
- PFA
- Note
- Other sizes can be evaluated through custom tooling on request
Product items
High-purity PFA connectors and fittings for semiconductor high-purity chemical supply, UPW piping, ICP-MS / ICP-OES tubing, and R&D fluid paths. Reduces container-borne contamination in low-background piping systems.
Material: PFA

| Spec | Model | Material | Size | Note |
|---|---|---|---|---|
| 2-way connector | 1/8 in, 1/4 in, 1/2 in, 1/4 to 1/8, 1/4 to 1/2 | Suited to straight-through connections, tubing extension, and reducing adaptation | PFA | Other sizes can be evaluated through custom tooling on request |
| 3-way connector | 1/8 in, 1/4 in, 1/2 in | Suited to flow splitting, merging, bypass, or multi-line piping configurations | PFA | Fitting type and tubing configuration can be confirmed on request |
High-purity PFA connectors and fittings for semiconductor high-purity chemical supply, UPW piping, ICP-MS / ICP-OES tubing, and R&D fluid paths. Reduces container-borne contamination in low-background piping systems.
PFA fittings are commonly used in tubing connections that need high cleanliness, corrosion resistance, and low background-contamination risk. Compared with ordinary metal or plastic fittings, PFA is better suited to some acidic and alkaline chemicals, high-purity reagents, semiconductor wet processes, and trace-analysis-related tubing. Two-way fittings suit straight-through connections, tubing extension, and reducing transitions; three-way fittings suit splitting, merging, bypass, or multi-line configurations. Selection must be confirmed against tubing size, fluid type, pressure, temperature, flow rate, and cleaning procedure.
Suited to semiconductor, high-cleanliness laboratory, and chemical-tubing workflows, helping reduce the background-contamination risk from ordinary fitting materials.
The flared-bead connection design helps improve the stability and ease of handling of PFA tubing connections; actual sealing performance must be confirmed against conditions of use.
Two-way fittings suit straight-through connections and transitions; three-way fittings suit splitting, merging, bypass, or multi-line configurations.
Common sizes of 1/8, 1/4, and 1/2 inch are offered, making it easy to pair with existing PFA tubing, valves, and equipment.
Two-way fittings come in 1/4 to 1/8 and 1/4 to 1/2 specifications, suiting transitions between different tubing diameters.
Other sizes or special fittings can be evaluated for customization according to tubing, fitting, equipment, or experimental workflow needs.
PFA fittings can be selected as two-way, three-way, or reducing-transition specifications according to the tubing configuration. For semiconductor chemicals, high-purity reagents, acidic and alkaline liquids, or trace-analysis sample-preparation systems, we recommend also confirming the PFA tubing size, fitting type, fluid direction, pressure, flow rate, and cleaning procedure.
To help confirm suitable PFA fittings, sizes, and tubing configuration, we recommend providing the following information:
PFA fittings suit high-cleanliness chemical tubing, transfer of acidic and alkaline liquids, semiconductor wet processes, laboratory fluid control, and trace-analysis sample-preparation systems. Actual suitability still needs to be confirmed against tubing size, chemical, concentration, temperature, pressure, flow rate, and fitting type.
Two-way fittings are mainly used for single-path straight-through connections, tubing extension, or reducing transitions; three-way fittings can be used for splitting, merging, bypass, or multi-line configurations. The actual choice must be confirmed against the tubing flow and fluid direction.
Two-way fittings come in 1/8 inch, 1/4 inch, 1/2 inch, 1/4 to 1/8, and 1/4 to 1/2; three-way fittings come in 1/8 inch, 1/4 inch, and 1/2 inch.
How to pair them with PFA tubing, PFA valves, or other fluoropolymer tubing components can be confirmed on request. The actual tube diameter, fitting type, and sealing method must be confirmed against the on-site tubing configuration.
PFA can be used in workflows involving many acids, bases, and some organic solvents, but actual suitability must be confirmed against chemical type, concentration, temperature, pressure, flow rate, and contact time.
These sizes denote reducing transitions, used for connections between different tubing sizes. The actual pairing still needs confirmation of tubing material, fitting type, flow direction, pressure, and sealing needs.
Custom tooling for other sizes or special fittings can be evaluated on request. Actual feasibility must be confirmed against dimensions, quantity, manufacturing conditions, and use requirements.
PFA fittings are commonly used in high-cleanliness, corrosion-resistant tubing workflows and can be applied to transfer of semiconductor chemicals and high-purity reagents. For trace-contamination control, we recommend also confirming the cleaning procedure, blank verification, and wetted-material requirements.
We recommend providing the two-way or three-way requirement, tubing size, whether a reducing transition is needed, fluid type, concentration, temperature, pressure, flow rate, fitting type, whether it is used in a high-cleanliness workflow, and estimated quantity.
Please provide the two-way / three-way requirement, tubing size, whether a reducing transition is needed, fluid type, temperature and pressure conditions, fitting type, and operating environment, and we can help confirm a suitable specification.