Ultra-trace Analytics超微分析科技

Product items

PFA Condenser

PFA condenser as a corrosion-resistant alternative to glass for HF, strong acid, and strong alkali reflux, distillation, and cooling. Integratable into high-cleanliness lab apparatus.

Material: PFA

PFA Condenser

Applications

Reflux and distillationCooling for HF / strong acid / strong alkaliHigh-cleanliness lab apparatusExperiments involving semiconductor chemicals, high-purity reagents, and wet processesPairing with PFA reaction vessels, flasks, and collection bottlesTrace-analysis sample prep, absorption, and condensation workflowsR&D labs, chemical synthesis, QC, and third-party testing workflowsHigh-cleanliness reaction setups that require low background-contamination risk

PFA 冷凝管規格

250 mL

Model
250
Material
PFA
Size
250
Note
可依需求確認直形或蛇形冷凝配置

300 mL

Model
300
Material
PFA
Size
300
Note
可依需求確認直形或蛇形冷凝配置

350 mL

Model
350
Material
PFA
Size
350
Note
可依需求確認直形或蛇形冷凝配置

500 mL

Model
500
Material
PFA
Size
500
Note
可依需求確認直形或蛇形冷凝配置

1000 mL

Model
1000
Material
PFA
Size
1000
Note
可依需求確認直形或蛇形冷凝配置

Product description

PFA condenser as a corrosion-resistant alternative to glass for HF, strong acid, and strong alkali reflux, distillation, and cooling. Integratable into high-cleanliness lab apparatus.

Why choose a PFA condenser

PFA condensers are used in reflux, distillation, condensation, and gas-absorption workflows that need corrosion resistance, high cleanliness, and low background-contamination risk. Compared with standard glass condensers, PFA is the better fit for some strong-acid, acidic-gas, high-purity-chemical, and semiconductor-lab workflows. The translucent body helps with observing condensate, flow paths, and operating state; straight or coil configurations can be chosen based on the reaction setup, condensation needs, and companion vessels.

主要特色

High-cleanliness PFA material

Suited to semiconductor, high-cleanliness lab, and corrosion-resistant reaction workflows. Helps reduce contamination variables from generic condenser materials.

Translucent for visibility

The translucent body helps with observing condensate, vapor channels, flow paths, and the operating state of the experimental setup.

Straight / coil configuration choice

A straight or coil condensation structure can be confirmed based on condensation needs, available space, reaction conditions, and companion vessels.

Compatible with reaction-setup accessories

Can be paired with PFA flasks, reaction vessels, collection bottles, absorption bottles, tubing, and fittings.

Multiple sizes 250–1000 mL

Available in 250, 300, 350, 500, and 1000 mL — all with 46 mm diameter and overall lengths from 400 to 1200 mm.

Straight / coil condenser and companion setup confirmation

The PFA condenser can be confirmed as straight or coil configuration and paired with flasks, reaction vessels, collection bottles, absorption bottles, tubing, and fittings. For acidic-gas, HF-related, reflux, or distillation-condensation use, first confirm reaction conditions, cooling method, fitting layout, and safety needs.

  • Required size: 250, 300, 350, 500, or 1000 mL
  • Whether a straight or coil configuration is needed
  • Whether pairing with flasks, reaction vessels, collection bottles, or absorption bottles
  • Whether gas inlet, vent, coolant, or tubing fittings are needed
  • Chemical, acid system, gas, or solvent used
  • Whether HF, acidic gases, or corrosive vapors are involved
  • Operating temperature, pressure, cooling method, and duration
  • Whether for semiconductor, high-cleanliness, or trace-analysis workflows
  • Whether custom fittings or comparison with existing equipment is needed
  • Estimated quantity and delivery timing

How to quickly confirm a suitable specification

To help confirm the right PFA condenser specification, condensation configuration, and companion setup, please share the following:

  • Required size or expected reaction volume
  • Whether a straight or coil condenser is needed
  • Specifications of reaction vessels, flasks, collection bottles, or absorption bottles
  • Chemical, acid system, gas, or solvent used
  • Whether HF, acidic gases, or corrosive vapors are involved
  • Operating temperature, pressure, cooling method, and duration
  • Fitting size, tubing direction, or photos of existing equipment
  • Whether for semiconductor, high-cleanliness, or trace-analysis workflows
  • Whether a custom design or companion parts are needed
  • Estimated quantity and delivery timing

How to choose a PFA condenser specification

  • 250 / 300 mL: suits small reactions, method development, small-volume reflux, or compact condensation setups
  • 350 / 500 mL: suits general lab reactions, reflux, distillation, or medium-scale condensation needs
  • 1000 mL: suits larger reaction volumes, longer condensation paths, or workflows that need a larger condensation setup
  • For higher condensation efficiency: confirm straight or coil configuration, overall length, cooling method, and vapor conditions
  • For HF or acidic gases: first confirm concentration, temperature, gas flow rate, cooling method, absorption stage, and safety specifications
  • For high-cleanliness or trace-analysis use: pair with the lab's existing cleaning, acid-wash, blank-verification, and clean-storage procedures

FAQ

What applications does the PFA condenser suit?

The PFA condenser suits corrosion-resistant reflux, distillation, condensation, acidic-gas handling, reaction-setup pairing, and high-cleanliness experimental workflows. Actual suitability is confirmed against chemical, concentration, temperature, pressure, cooling method, and safety conditions.

Need to confirm PFA condenser specification, configuration, or companion setup?

Share required specification, straight / coil preference, chemical used, temperature/pressure conditions, cooling method, and companion flask or collection-bottle info, and we will help confirm a suitable specification.