450 mL
- Model
- 84 × 84 × 80 mm
- Material
- PFA
- Size
- 450 mL
- Note
- 可搭配 PFA 酸槽蓋,適合小型器皿浸泡與清洗
Product items
PFA acid cleaning tank for HF, HCl, HNO3 acid soaking and washing of containers, fixtures, and wafers. Maintains a low-metal-background cleaning environment.
Material: PFA

| Spec | Model | Material | Size | Note |
|---|---|---|---|---|
| 450 mL | 84 × 84 × 80 mm | PFA | 450 mL | 可搭配 PFA 酸槽蓋,適合小型器皿浸泡與清洗 |
| 1000 mL | 205 × 85 × 80 mm | PFA | 1000 mL | 可搭配 PFA 酸槽蓋,適合長形器皿或少量批次清洗 |
| 9 L | 356 × 246 × 125 mm | PFA | 9 L | 可搭配 PFA 酸槽蓋,適合中型器皿浸泡與批次酸洗 |
| 14 L | 415 × 265 × 156 mm | PFA | 14 L | 可搭配 PFA 酸槽蓋,適合較大量器皿清洗與浸泡 |
| 15 L | 300 × 210 × 240 mm | PFA | 15 L | 可搭配 PFA 酸槽蓋,適合較高器皿或較深浸泡需求 |
| 20 L | 390 × 280 × 205 mm | PFA | 20 L | 可搭配 PFA 酸槽蓋,適合大量清洗、浸泡與高潔淨前處理 |
PFA acid cleaning tank for HF, HCl, HNO3 acid soaking and washing of containers, fixtures, and wafers. Maintains a low-metal-background cleaning environment.
PFA cleaning tanks are used in labware acid washing, sample soaking, sample-prep cleaning, and trace-analysis workflows that require high cleanliness, chemical compatibility, and low background-contamination risk. Compared with standard PP, PE, or glass tanks, PFA is the better fit for some strong-acid, high-purity-chemical, semiconductor-sample, and trace-metals workflows. The one-piece, seamless construction reduces cleaning dead spots, liquid residue, and contamination buildup. Pairing with a PFA tank lid helps limit external contamination, evaporation, and foreign-particle ingress.
Suited to semiconductor, high-cleanliness lab, and trace-analysis cleaning workflows. Helps reduce background contamination from generic tank materials.
One-piece construction reduces welded seams, cleaning dead spots, and residue risk — suited to high-cleanliness acid-wash and soaking workflows.
A PFA tank lid can be paired on request to help reduce external contamination, evaporation, and foreign-particle ingress.
Suitable for labware acid washing, soaking, cleaning, sample prep, and high-purity-chemical workflows. Actual conditions depend on the acid system.
Available in 450 mL, 1000 mL, 9 L, 14 L, 15 L, and 20 L — pick based on labware size, liquid volume, and batch needs.
Custom sizes or configurations can be evaluated against your cleaning workflow, labware size, tank-space constraints, lid needs, and operating environment.
The PFA cleaning tank can be paired with a PFA lid for labware acid washing, soaking, cleaning, and high-cleanliness sample-prep workflows. For ICP-MS, trace-metals analysis, semiconductor contamination analysis, or high-purity-chemical workflows, please confirm acid system, concentration, cleaning procedure, blank verification, and safety conditions in parallel.
Share labware size, cleaning quantity, acid type, concentration, operating temperature, soaking time, and whether a tank lid is needed, and we will help confirm a suitable specification.