15 mL
- 外徑 mm
- 16
- 高度 mm
- 122
- 備註
- 尖底,管身可依需求評估標刻度
Product items
PFA centrifuge tube with screw cap, centrifuge-compatible. Suitable for high-cleanliness labs, semiconductor trace analysis, ICP-MS sample prep, acid / alkali sample handling, and low-background contamination control. Available in 10 / 15 / 25 / 50 mL.
Material: High-purity PFA

| Spec | 外徑 mm | 高度 mm | 備註 | Note |
|---|---|---|---|---|
| 15 mL | 16 | 122 | 尖底,管身可依需求評估標刻度 | 尖底,管身可依需求評估標刻度 |
| 50 mL | 29 | 130 | 尖底,管身可依需求評估標刻度 | 尖底,管身可依需求評估標刻度 |
PFA centrifuge tube with screw cap, centrifuge-compatible. Suitable for high-cleanliness labs, semiconductor trace analysis, ICP-MS sample prep, acid / alkali sample handling, and low-background contamination control. Available in 10 / 15 / 25 / 50 mL.
PFA centrifuge tubes are used in sample-dispensing, storage, and centrifugation workflows that need high cleanliness, chemical compatibility, and low background-contamination risk. Compared with standard PP or PE centrifuge tubes, PFA is the better fit for some acidic samples, high-purity chemicals, and trace-metals analysis applications. The conical bottom aids sample sedimentation and small-volume recovery; the tube body can carry graduation markings on request for easier sample management, volume identification, and workflow recording.
Suited to semiconductor, high-cleanliness lab, and trace-analysis sample-handling workflows. Helps reduce background contamination from generic container materials.
The conical-bottom structure suits sample sedimentation, separation, and small-volume recovery, easing sample prep and management.
Tube-body graduations can be evaluated on request to aid volume identification, sample dispensing, and workflow recording.
Graduations, sizes, packaging, and other custom items can be evaluated per application needs. Feasibility is confirmed against specifications and manufacturing conditions.
Available in 15 mL and 50 mL — choose based on sample volume, centrifugation workflow, and lab operating needs.
To help confirm the right PFA centrifuge tube specification, graduations, and use conditions, please share the following:
PFA centrifuge tubes suit high-cleanliness sample dispensing, centrifugation, sedimentation-based separation, sample storage, and trace-analysis sample-prep workflows. Actual suitability is confirmed against sample type, acid system, centrifugation conditions, and analytical method.
PFA is used in sample workflows that need higher chemical compatibility, high cleanliness, and low background-contamination risk. Compared with standard PP or PE centrifuge tubes, PFA tubes fit some acidic-sample, high-purity-chemical, and trace-analysis applications better — but the final choice depends on sample and method conditions.
Yes — PFA centrifuge tubes can be used in sample-dispensing, storage, and handling workflows associated with sample prep for ICP-MS, ICP-OES, AAS, and similar. For trace-metals analysis, pair with the lab's existing cleaning, acid-wash, blank-verification, and clean-storage procedures.
The product data does not list a fixed speed or RCF. Actual centrifugation conditions are confirmed against centrifuge, rotor, tube rack, sample density, volume, temperature, and safety specifications. When inquiring, please share expected speed, RCF, and centrifugation time.
Yes — tube-body graduations can be evaluated on request to aid volume identification and sample management. Actual marking style and feasibility are confirmed against specifications, quantity, and manufacturing conditions.
Yes — custom items such as graduations, sizes, markings, or packaging style can be evaluated on request. Feasibility is confirmed against specifications, manufacturing conditions, and quantity.
Available in 15 mL and 50 mL. The 15 mL has 16 mm outer diameter and 122 mm height; the 50 mL has 29 mm outer diameter and 130 mm height.
Please share required volume, sample type, acid system or solvent, whether for centrifugation, centrifuge / rotor info, expected speed or RCF, whether graduations are needed, and whether the use is in trace-analysis or high-cleanliness workflows.
Share sample type, acid system or solvent, required volume, centrifuge / rotor info, expected speed / RCF, whether tube-body graduations are needed, and the analytical method, and we will help confirm a suitable specification.
實際適用樣品、酸鹼條件、離心轉速、RCF、轉子型式、管架匹配與使用方法,需依實際條件確認。