Ultra-trace AnalyticsUltra-trace Analytics

Product items

PFA Buchner Funnel | Ultra-clean Vacuum Filtration & Trace Analysis Prep | Ultra-trace Analytics

PFA Buchner Funnel

A one-piece Buchner funnel made of high-purity PFA, with a configurable screen plate, suited to high-cleanliness vacuum filtration, solid-liquid separation, filtration of acidic and alkaline samples, and trace-analysis sample preparation workflows, offered in 500 mL and 600 mL sizes.

Material: High-purity PFA

PFA Buchner funnel made from high-purity PFA with integrated structure and optional sieve plate for ultra-clean vacuum filtration and trace analysis preparation

Applications

Ultra-clean vacuum filtration and solid-liquid separationAcidic and alkaline sample filtration and pre-treatmentSemiconductor chemical sample handlingICP-MS / ICP-MS/MS / ICP-OES sample preparationTrace metals analysis filtration workflow

PFA Buchner funnel specifications

Spec

Model
—
Material
—
Size
—
Note
—

Spec

Model
—
Material
—
Size
—
Note
—

Product description

High-purity PFA Buchner funnel with one-piece construction and optional sieve plate for ultra-clean vacuum filtration, solid-liquid separation, acidic/alkaline sample filtration, and trace analysis preparation. Available in 500 mL and 600 mL.

PFA Buchner Funnel

The PFA Buchner funnel suits high-cleanliness laboratories, semiconductor trace analysis, ICP-MS sample preparation, filtration of acidic and alkaline samples, and low-background contamination control workflows. High-purity PFA offers good chemical resistance, and the one-piece design helps reduce the risk of seam residue and hard-to-clean areas. A screen plate can be configured as needed, and it can be used with a suitable vacuum filtration system.

Key features

High-purity PFA material

Suited to filtration and sample preparation workflows with high cleanliness and chemical-resistance requirements.

One-piece construction

Helps reduce seams and hard-to-clean areas, lowering residue risk.

Screen plate can be configured

A screen plate and filter-membrane support method can be configured according to application conditions.

500 mL and 600 mL sizes

Selectable by single-batch volume and filtration workflow needs.

Information to provide before selection and inquiry

  • • Required capacity: 500 mL or 600 mL
  • • Sample type and chemical conditions
  • • Acid system, base, solvent, or special matrix
  • • Whether it is used for ICP-MS, ICP-MS/MS, or trace metals analysis
  • • Whether it is used in semiconductor or high-cleanliness workflows
  • • Filtration purpose: solid-liquid separation, sample preparation, filtration of acid and base solutions, filter-membrane support, or filtration of high-purity chemicals
  • • Estimated volume per filtration and batch size
  • • Filter membrane, filter paper, or screen plate requirements
  • • Material, capacity, and connection method of the filter flask to be paired
  • • Vacuum conditions, operating temperature, and contact time
  • • Whether acid-wash, cleaning, or blank-verification procedures are needed
  • • Estimated quantity and lead time

Specifications

500 mLHigh-purity PFA | 120 mm | 23 mm | 82 mm | One-piece construction; screen plate can be configured
600 mLHigh-purity PFA | 97 mm | 10 mm | 165 mm | One-piece construction; screen plate can be configured

FAQ

Which applications suit the PFA Buchner funnel?

It suits high-cleanliness vacuum filtration, solid-liquid separation, filtration of acidic and alkaline samples, semiconductor trace analysis, ICP-MS sample preparation, and low-background contamination control workflows.

How does a PFA Buchner funnel differ from a PTFE Buchner funnel?

Both can be used for chemical-resistant filtration and high-cleanliness sample preparation. PFA generally offers better transparency and fit for high-cleanliness applications; PTFE is common in a broader range of chemical-resistant and corrosion-resistant equipment parts. Actual selection must be confirmed against sample, temperature, vacuum conditions, and cleaning workflow.

Can a PFA Buchner funnel be used with a filter flask?

It can be paired with a suitable filter flask and vacuum filtration system as needed. The actual connection, sealing method, vacuum conditions, and configuration should be confirmed against conditions of use.

Will a PFA Buchner funnel cause no contamination at all?

PFA helps reduce the background-contamination risk from contact materials, but actual contamination control still depends on the cleaning method, filter membrane or screen plate, reagent purity, storage method, operating environment, and laboratory SOP.

Need to confirm PFA Buchner funnel specifications, screen plate, or filtration configuration?

Please provide the sample liquid type, volume per filtration, chemical conditions, filter-membrane or screen-plate needs, the filter flask to be paired, and whether it is used for ICP-MS / trace metals analysis, and we can help confirm a suitable specification and application configuration.

Request a quote

Not sure about the spec? Upload a photo of your current part and we'll match it.

* Required

Application, chemicals, dimensions or anything else that helps us match the right item.

You can email photos to sales@ultra-trace.com.