100 mL
- Model
- 100
- Material
- PFA
- Size
- 100 mL
- Note
- 可依需求確認把手與蓋體配置
Product items
PFA beaker with graduations and a handle, for handling HF, strong acids, strong alkalis, and high-purity chemicals; ICP-MS sample prep; semiconductor trace analysis; and high-cleanliness lab work.
Material: PFA

| Spec | Model | Material | Size | Note |
|---|---|---|---|---|
| 100 mL | 100 | PFA | 100 mL | 可依需求確認把手與蓋體配置 |
| 250 mL | 250 | PFA | 250 mL | 可依需求確認把手與蓋體配置 |
| 500 mL | 500 | PFA | 500 mL | 可依需求確認把手與蓋體配置 |
| 1000 mL | 1000 | PFA | 1000 mL | 一體成型,可配 PFA 把手 |
| 2000 mL | 2000 | PFA | 2000 mL | 一體成型,可配 PFA 把手 |
| 5000 mL | 5000 | PFA | 5000 mL | 一體成型,可配 PFA 把手 |
PFA beaker with graduations and a handle, for handling HF, strong acids, strong alkalis, and high-purity chemicals; ICP-MS sample prep; semiconductor trace analysis; and high-cleanliness lab work.
PFA beakers with handles are used in liquid measurement, dispensing, acid/base handling, and sample-preparation workflows that need high cleanliness, chemical compatibility, and low background-contamination risk. Compared with standard glass, PP, or PE beakers, PFA is the better fit for some strong-acid, high-purity, semiconductor wet-process, and trace-analysis applications. The handle improves pickup, pouring, and transfer ergonomics for larger volumes. A PFA or PTFE lid can be paired on request if sample storage or external-contamination control is required.
Suited to semiconductor, high-cleanliness lab, and trace-analysis workflows. Helps reduce background-contamination risk from generic container materials.
The handle improves liquid pickup, pouring, and dispensing ergonomics, especially for larger-volume beakers.
PFA or PTFE lids can be paired depending on sample-storage, acid-wash, heated-prep, or dust-control needs.
1000, 2000, and 5000 mL sizes are available as one-piece moulds with a PFA handle, suiting larger-volume liquid handling.
Available in 100, 250, 500, 1000, 2000, and 5000 mL — pick based on liquid volume, workflow, and lab needs.
The handle style of the PFA beaker can be confirmed against volume and use, and PFA or PTFE lids can be paired. For high-purity chemicals, semiconductor contamination analysis, or trace-metals analysis, please confirm cleaning procedures, acid-wash conditions, lid material, and blank-verification needs in parallel.
Share volume needs, sample type, acid system or solvent, whether a handle is required, whether a PFA / PTFE lid is required, and the analytical method, and we will help confirm a suitable specification.